* NOTE: Image may not exactly match the product

Huawei S5731-S48S4X(48*GE SFP ports, 4*10GE SFP+ ports, without power module)

$Quote1 Piece(MOQ)

SKU S5731-S48S4X Categories , Brand:
100% New and Genuine
Million Models In St
Bulk Order Rebate
Fast Delivery
Payment:
Shipping:

Additional information

Airflow direction

Air intake from left, front and right, air exhaustion from behind

Maximum heat dissipation [BTU/hour]

439.79 (150 W AC or 180 W DC), 484.38 (600 W AC)

Heat dissipation mode

Heat dissipation with fan, intelligent fan speed adjustment

Short-term operating temperature [C(F)]

-5C to +50C (23F to 122F) at an altitude of 0-1800 m (0-5906 ft.)

Storage temperature [C(F)]

-40C to +70C (-40F to +158F)

Warranty

1 Year

Long-term operating altitude [m(ft.)]

0-5000 m (0-16404 ft.)

Console port

RJ45

Long-term operating temperature [C(F)]

-5C to +45C (23F to 113F) at an altitude of 0-1800 m (0-5906 ft.)

Storage altitude [m(ft.)]

0-5000 m (0-16404 ft.)

Typical power consumption [W]

93.69 W

Height [mm]

43.6 mm

Flash memory

The physical space is 1 GB. You can run the display version command to view the actual available space.

Power supply mode

Pluggable power supply

USB

Not supported

Number of card slots

0

Availability

> 0.99999

RPS input

Not supported

Depth [mm]

420.0mm

Typical heat dissipation [BTU/hour]

319.68 BTU/hour

RTC

Supported

Maximum power consumption [W]

128.89 W (150 W AC or 180 W DC), 141.96 W (600 W AC)

MTTR [hours]

2 hours

Brand

Huawei

Rated input voltage [V]

AC input: 100 V AC to 240 V AC, 50/60 Hz, High-voltage DC input: 240 V DC, DC input: C48 V DC to C60 V DC

Memory

2 GB

Input voltage range [V]

AC input: 90 V AC to 290 V AC; 45 Hz to 65 Hz, High-voltage DC input: 190 V DC to 290 V DC, DC input: C38.4 V DC to C72 V DC

Types of fans

Built-in

PoE

Not supported

Products Status

New

Static power consumption [W]

50.44 W

Eth Management port

RJ45

Weight with packaging [kg(lb)]

7.65 kg (16.87 lb)

Long-term operating relative humidity [RH]

5% to 95%, noncondensing

Noise at normal temperature (acoustic power) [dB(A)]

45.47 dB(A)

Noise at normal temperature (acoustic pressure) [dB(A)]

31.79 dB(A)

Redundant power supply

1+1, Pluggable AC and DC power modules can be used together in the same switch, but power modules that use natural heat dissipation and power modules that use air cooling cannot be used together.

Dimensions with packaging (H x W x D) [mm(in.)]

185 mm x 650 mm x 550 mm (7.28 in. x 25.59 in. x 21.65 in.)

MTBF [years]

64.97 years

PN

98011805

Ingress protection level (dustproof/waterproof)

IP20

Certification

EMC certification, Safety certification, Manufacturing certification

Service port surge protection [kV]

Maximum input current [A]

The current specifications depend on the pluggable power modules in use. For details, see the related power module specifications.

Number of power slots

2

Power supply surge protection [kV]

Configured with AC power modules: 6 kV in differential mode and 6 kV in common mode, Configured with DC power modules: 2 kV in differential mode and 4 kV in common mode

Model

S5731-S48S4X

Weight without packaging [kg(lb)]

5.12 kg (11.29 lb)

Number of fans modules

3

Chassis height [U]

1

Wide [mm]

442.0mm

Submit Inquiry

Buy more, save more. Contact us for exclusive discounts!