Airflow direction

Air intake from front, air exhaustion from rear (front-to-rear)

Heat dissipation mode

Heat dissipation with fan, intelligent fan speed adjustment

Weight without packaging

5.28 (11.64)

Power supply surge protection

– Configured with AC power modules: 6 kV in differential mode and 6 kV in common mode, – Configured with DC power modules: 2 kV in differential mode and 4 kV in common mode

10GE optical interface

4

Long-term operating temperature

-5C to +45C (23F to 113F) at an altitude of 0-1800 m (0-5906 ft.)

Warranty

1 Year

Console port

RJ45

1000M electrical interface

24

Typical power consumption [W]

88

Height [mm]

43.6 mm

Flash memory

1 GB in total. To view the available flash memory size, run the display version command.

Power supply mode

Pluggable power supply

MTBF [year]

57.73

USB

Supported

Number of card slots

0

MTTR [h]

2

Availability

>0.99999

RPS input

Not supported

Depth [mm]

420.0mm

Storage temperature

-40C to +70C (-40F to +158F)

Maximum power consumption [W]

114

Brand

Huawei

Rated input voltage [V]

– AC input: 100C240 V AC; 50/60 Hz – High-voltage DC input: 240 V DC – DC input: C48 V DC to C60 V DC

Memory

2 GB

Input voltage range [V]

– AC input: 90 V AC to 290 V AC; 45 Hz to 65 Hz, – High-voltage DC input: 190 V DC to 290 V DC, BL15 – DC input: C38.4 V DC to C72 V DC

Types of fans

Pluggable

PoE

Not supported

Products Status

New

Noise at normal temperature (acoustic power)

57.5

Long-term operating altitude

0-5000 m (0-16404 ft.)

Eth Management port

RJ45

Service port surge protection

Common mode: 6 kV

Long-term operating relative humidity [RH]

5% to 95%, noncondensing

Weight with packaging

8.4 (18.52)

Redundant power supply

1+1, Pluggable AC and DC power modules can be used together in the same switch, but power modules that use natural heat dissipation and power modules that use air cooling cannot be used together.

Noise at normal temperature (acoustic pressure)

47.5

PN

02353AHU

Maximum input current [A]

The current specifications depend on the pluggable power modules in use. For details, see the related power module specifications.

Number of power slots

2

Model

S5731-S24T4X

Storage altitude

0-5000 m (0-16404 ft.)

Typical heat dissipation [BTU/h]

300.26

Chassis height [U]

1

Maximum heat dissipation [BTU/h]

389