* NOTE: Image may not exactly match the product

Huawei S5720-52X-SI-AC(48 Ethernet 10/100/1000 ports,4 10 Gig SFP+,with 150W AC power supply)

$Quote1 Piece(MOQ)

SKU S5720-52X-SI-AC Categories , Brand:
100% New and Genuine
Million Models In St
Bulk Order Rebate
Fast Delivery
Payment:
Shipping:
PN 02350DLV
Model S5720-52X-SI-AC
Brand Huawei
Warranty 1 Year
Products Status New
Height [mm] 44.4 mm
Depth [mm] 424.7mm
Wide [mm] 442.0mm
Memory (RAM) 512 MB
Flash 512 MB in total. To view the available flash memory size, run thedisplay versioncommand.
Mean time between failures (MTBF) 73.23 years
Mean time to repair (MTTR) 2 hours
Availability > 0.99999
Service port surge protection Common mode: 6 kV
Power supply surge protection Using AC power modules: 6 kV in differential mode, 6 kV in common mode, Using DC power modules: 1 kV in differential mode, 2 kV in common mode
Dimensions (H x W x D) Basic dimensions (excluding the parts protruding from the body): 44.4 mm x 442.0 mm x 424.7 mm (1.75 in. x 17.4 in. x 16.72 in.), Maximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 44.4 mm x 442.0 mm x 451.8 mm (1.75 in. x 17.4 in. x 17.79 in.)
Weight (with packaging) 9.5 kg (20.95 lb)
Stack ports GE electrical ports and 10GE SFP+ optical ports on the front panel
RTC Supported
RPS Not supported
PoE Not supported
Rated voltage range 100 V AC to 240 V AC, 50/60 Hz, -48 V DC to -60 V DC
Maximum voltage range 90 V AC to 264 V AC, 47 Hz to 63 Hz, -36 V DC to -72 V DC
Maximum power consumption (100% throughput, full speed of fans) 56.8 W
Typical power consumption (30% of traffic load) Tested according to ATIS standard EEE enabled No PoE power consumption 33.8 W
Operating temperature 0C to 45C (32F to 113F) at an altitude of 0-1800 m (0-5906 ft.), NOTE: When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1C (1.8F) every time the altitude increases by 220 m (722 ft.).
Short-term operating temperature -5C to +50C (23F to 122F) at an altitude of 0-1800 m (0-5906 ft.), NOTE: When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1C (1.8F) every time the altitude increases by 220 m (722 ft.). The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met: The equipment operates at a temperature of over 45C (113F) consecutively for at most 96 hours in one year. The equipment operates at a temperature of over 45C (113F) for a total of no more than 360 hours in one year. The equipment operates at a temperature of over 45C (113F) for no more in 15 times in one year. The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded. The equipment cannot start when the temperature is lower than 0C (32F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.
Storage temperature -40C to +70C (-40F to +158F)
Noise under normal temperature (27C, sound power) < 52 dB(A)
Relative humidity 5% to 95%, noncondensing
Operating altitude AC power modules configured: 0-5000 m (0-16404 ft.), DC power modules configured: 0-2000 m (0-6562 ft.)
Certification EMC certification, Safety certification, Manufacturing certification

Submit Inquiry