Weight (with packaging) | 4.08 kg (9 lb) |
---|---|
Power supply surge protection | 6 kV in differential mode, 6 kV in common mode |
Dimensions (H x W x D) | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.7 in.), Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.) |
Mean time between failures (MTBF) | 111.94 years |
Flash | 512 MB in total. To view the available flash memory size, run thedisplay versioncommand. |
Warranty | 1 Year |
Typical power consumption (30% of traffic load) Tested according to ATIS standard EEE enabled No PoE power consumption | 28 W |
Operating temperature | -5C to +45C (23F to 113F) at an altitude of 0-1800 m (0-5906 ft.) NOTE: When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1C (1.8F) every time the altitude increases by 220 m (722 ft.). The switch cannot be started when the ambient temperature is lower than 0C (32F). The operating temperature of the switch is -5C to +40C (23F to 104F) when it uses GE SFP optical modules with 40 km or longer transmission distance. When SFP+ copper cables or dedicated stack cables are used to set up a stack, the switch can operate in the following temperature range: -5C to +45C (23F to 113F) (installed in the ventilation cabinet, with the wind speed of at least 40 LFM) When SFP+ AOC cables or 10GE SFP+ optical modules are used to set up a stack, the switch can operate in the following temperature range: -5C to +45C (23F to 113F) (installed in the ventilation cabinet shipped with fans with a fan speed of at least 200 LFM) |
Height [mm] | 43.6 mm |
Relative humidity | 5% to 95%, noncondensing |
RPS | Not supported |
Operating altitude | 0-5000 m (0-16404 ft.) |
Noise under normal temperature (27C, sound power) | Noise-free (no fans) |
Availability | > 0.99999 |
Depth [mm] | 220.0mm |
RTC | Not supported |
Rated voltage range | AC input: 100 V AC to 240 V AC, 50/60 Hz, High-Voltage DC input: 240 V DC |
Mean time to repair (MTTR) | 2 hours |
Storage temperature | -40C to +70C (-40F to +158F) |
Maximum voltage range | AC input: 90 V AC to 264 V AC, 47 Hz to 63 Hz, High-Voltage DC input: 190 V DC to 290 V DC |
Brand | Huawei |
PoE | Not supported |
Products Status | New |
Memory (RAM) | 1 GB |
Service port surge protection | Common mode: 7 kV |
Stack ports | Any 10/100/1000BASE-T ports or 1000BASE-X ports (applicable in V200R019C10 and later versions) |
PN | 98010914 |
Certification | EMC certification, Safety certification, Manufacturing certification |
Model | S5735-L24T4S-A |
Maximum power consumption (100% throughput) | 34 W |
Chassis height [U] | 1 |
Wide [mm] | 442.0mm |
Huawei S5735-L24T4S-A (24 x 10/100/1000Base-T ports, 4 x GE SFP ports)